Box Strength Calculator
Will your box survive the stack? Enter your board grade and dimensions.
Result
Results appear here as you type. This calculator needs JavaScript switched on.
How this calculator works
The lab strength of a box (BCT, box compression test) is estimated with the simplified McKee formula, which links box strength to the board and the box size:
BCT = 5.87 × ECT × √(board thickness × box perimeter)
The box perimeter is 2 × (length + width). For most boxes the height has little effect; very shallow boxes are usually stronger than the formula says.
Lab strength is measured at 23 °C and 50% humidity over a few minutes. Real stacks stand for weeks in humid air, so the calculator multiplies the lab strength by typical published loss factors:
| Condition | Strength kept |
|---|---|
| Humidity 60% / 70% / 80% / 90% | 90% / 80% / 68% / 48% |
| Stack stands 10 / 30 / 90 / 180 days | 63% / 60% / 55% / 50% |
| Columns slightly out of line | 87% |
| Interlocked (brick) stacking | 50% |
| Overhang at the pallet edge | 70% |
| Wide gaps between pallet top boards | 83% |
The load on the bottom box is the weight of every box above it plus any extra load. If the usable strength is less than that load, the bottom box is likely to buckle over time.
This is an estimate from the numbers you enter, using standard formulas and published industry guidelines. It is not a design approval or a test result. Always confirm packaging with physical testing before production. See our Terms of Use.